PAPT-B01 Air Permeability Tester

PAPT-B01 Air Permeability Tester is used to test the air permeability of polymer materials, films, paper and paperboard, etc. with Bentsen method (Golley or Schober method is optional).
Product Introduction

PAPT-B01 Air Permeability Tester is used to test the air permeability of polymer materials, films, paper and paperboard, etc. with Bentsen method (Golley or Schober method is optional).


Features


● Three test methods are available: Gurley method, Schober method and Bendtsen method.

● The pressure difference of the instrument is adjustable in the range of 0-3KPa, with an accuracy of 0.01kPa, which fully meets the test pressure difference requirements of the three methods

● The instrument has a large test volume of 1L, which fully meets the volume requirements of the three methods

● The test area of 10.0cm2 and 6.42cm2 can be freely converted by adding a mask

● The instrument comes with a temperature and humidity sensor to monitor the temperature and humidity of the test chamber in real time.

● The instrument has good sealing performance, and the air leakage does not exceed 1.0ml/h

● Dual-mode control of the instrument (computer software is optional)


Technical Specification


ItemParameter
Measuring Range0.01-2.5um/(Pa.s)
Resolution0.001um/(Pa.s)
Permeation Rate0.01-120ml/min (Customization available)
Pressure Difference/Accuracy0-3KPa /±0.01kPa (Customziation available)
Valid Pressure DifferenceGurley method: 1.21kpa
Bendtsen method: 1.47kPa±0.02kPa
Schober method: 1.00 kPa±0.01kPa /2.50±0.01kPa (Air flow less than 0.13ml/L)
Test AreaBendtsen method: 50mm×50mm Valid area: 10.0±0.2cm2
Schober method: 60mm×100mm Valid area: 10.0±0.2cm2
Gurley method: 50mm×50mm Valid area:6.42cm2
Test Time1-999999s  Accuracy: 0.1s
     Sample ConditioningA. Pretreatment: <40℃, 10-35%RH atmospheric conditions, stand for 24h
B.The difference between the previous and the next weighing at an interval of 1 hour is not greater than 0.25% of the total mass
Instrument Dimension420(L)X 300(B)X 165(H)mm
Power Supply220V/50Hz  100w
Weight15kg


Testing Principle


Bendtsen method: Under a constant pressure difference of 1.47kPa, record the gas flow through the test surface after clamping for 5 seconds.

Schober method: Under a constant pressure difference of 1.00kPa±0.01 kPa or 2.50±0.01kPa, select an appropriate test duration and measure the gas flow through the sample by the test volume.

Gurley method: Under a constant pressure difference of 1.23kPa, measure the time taken for 100 ml of gas to pass through.


Test standard


ISO 5356


Configuration


Standard Configuration: Main instrument, power cord

Optional: Computer software

Note: Air sources shall be prepared by the user